FLASH SALE: EVERYTHING HALF PRICE! LIMITED TIME ONLY!
MIRA Safety NBC-77 SOF 40mm Gas Mask Filter Sale!

MIRA Safety NBC-77 SOF 40mm Gas Mask Filter

  • $81.99
  • $41.00

The NBC-77 SOF filter canister, in combination with a full-face mask, mouthpiece assembly or PAPR provide reliable protection of air passages against a wide range of harmful and highly toxic substances includingall known CBRN agents.Filters are produced wi

  • 100% Happiness Backed or Your Money Back
  • Free Delivery on 30+ Orders
  • 60-Day Hassle-Free Returns

SKU: DR402366170

Category:

The NBC-77 SOF filter canister, in combination with a full-face mask, mouthpiece assembly or PAPR provide reliable protection of air passages against a wide range of harmful and highly toxic substances includingall known CBRN agents.Filters are produced with standard round threads according to STANAG 4155 (EN 148- 1)- Rd 40×1/7″ or GOST 8762-75 – 40×4 mm. Filter components are made of hard plastic. It provides a very robust product which is extremely durable against shock and impact damage in operational use.

APPLICATION:

The filter canister in connection with suitable respirator or PAPR provides protection against solid and liquid particles, pepper spray (OC), smokeproducing substances, radioactive particles, bacteria and rickettsia, fungi, toxins, viruses, Riot Control agents (Lachrymators, Sternutators, Vomiting agents), Blister agents (Vesicants), Chocking agents, Blood agents, Nerve agents, Incapacitants, Herbicides, Pesticides and TIC, such as bromoacetone, CS, CR, CN, CNC, CNS, CA substances, organic compounds of arsenic – diphenyldichlorarsine – CLARK I(DA), diphenylcyanoarsine – CLARK II (DC), adamsite (DM), diphenyldichlorarsine (DA), ethyldichlorarsine (ED), methyldichlorarsine (MD), mustard gas (H), sulphur mustard gas (HD), T-mustard gas, Q-mustard gas, nitrogen mustard gases (HN1, HN2, HN3), lewisite (L), mixed mustard gas (H-L), phosgene oxime (CX), phosgene (CG), diphosgene(DP), chloropicrin (PS), hydrogen cyanide (AC), cyanogen chloride (CK), arsine (SA), G-agents: sarin (GB), cyclosarin (GF), soman (GD), tabun (GA), IVA (GV), V-agents: VX, VR, VE, VG (amiton), VM and toxic industrial chemicals such as: fumes of organic or inorganic acids, hydroxides, organic solvents with the boiling point above 65 C, ammonia, amines, inorganic and acid gases, agricultural chemical combustion gases, other toxic substances, e.g. benzene, toluene, vinyl chloride, fluorine, hydrogen fluoride, sulphur oxides, chloracetic acid, aldehydes, mixtures of inorganic acids, and organic substances, mercury vapours,radioactive iodine, organic compounds of iodine (Iodomethane, 129, 131), radioactive particles,etc.

LIFETIME:

Breakthrough time of a filter is tested according to EN 14387+A1 at humidity 70% and flow rate 30 l/min, which is equivalent to the volume of air per minute used by an average person carrying out medium heavy work. The approximate lifetime (usage time) of a filter may, under normal conditions, calculated by comparing the concentration at the workplace and the minimum Dynamic Adsorption Capacity (DAC) for the filter.

STORAGE AND MAINTENANCE:

The filters are sealed in plastic bags by the manufacturer. Store the filters unopened in a clean place at even temperature, most appropriate at -5 to +30C and relative humidity below 80%. Sealed filters tolerate also conditions of -30 to +50C and RH below 95%. The storage period (month and year) for filters is marked on the filter label. Do not try to regenerate the filters. Never clean the filters with compressed air or compressed water.

DISPOSAL:

After use, the filters are special refuse. Make sure that they are disposed of according to the filtered substance (gases or particles) in accordance with current waste treatment regulations. If the product is to be disposed of, it should be dismantled from the respirator and disposed of as solid waste. Please see local authority regulations for disposal advice and locations.

Testing Gas Concentration of testing gas Breakthrough time in minutes EN requirement NBC-77 SOF DAC in grams NBC – 77 SOF
ppm mg/I
A2 Cyclohexane CH 5000 17.5 35 39 20,475
B2 Chlorine Cl 5000 15 20 45 20,250
Hydrogen Sulphide HS 5000 7.1 40 >80 >17,400
Hydrogen Cyanide HCN 5000 5.6 25 50 8,400
E2 Sulfur dioxide SO 5000 13.3 20 25 9,975
K2 Ammonia NH 5000 3.5 40 50 5,250
Hg Mercury Hg —— 13 mg/m 100 hours >170 hours >3900
SX Cyanogen chloride CICN 2500 6.28 20 25 4,710
Chloropicrin CCINO 5000 33.55 20 44 44,286
Phosgene COCl 5000 20.24 20 >77 >47,058
REACTOR Methyloidide131 CHI 2 hours >2 hours

Dimensions w x h

110 x 85 mm
Weight 335 g
Connection Thread STANAG 4155 / EN 148-1 or GOST

Cost:

$25

Free Shipping:

We offer free shipping on orders over $30. Please check the free - shipping eligibility at checkout.

Delivery Time:

It usually takes [3-5] business days for standard shipping. Please note that this is an estimated time frame and may be affected by local holidays, and unforeseen circumstances.

Reviews

There are no reviews yet.

Be the first to review “MIRA Safety NBC-77 SOF 40mm Gas Mask Filter”

Your email address will not be published. Required fields are marked *